E-mail: service@1001718.com
Universal IV ™ Cut Monitor Model
Universal IV ™ Cut Monitor ModelOverviewThe Universal IV CM is a Water CUt Monitor that is built upon 50 years of applications expertise with RF Admittance.
Universal IV ™ Cut Monitor Model的详细资料
Universal IV ™ Cut Monitor Model
The Universal IV CM has a range of 0-50% in light oil and 0-80% in heavy oil. Our probes can handle pressures up to 1500 PSI and temperatures up to 450°F.
Applications
Use the Best Universal IV ™ Cut Monitor Model
For over 50 years, Drexelbrook has established itself as the world’s leader in capacitive based water cut measurements.
Easy Calibration - Now with Built-in LCD Display and Keypad
All Universal IV CM comes from the factory pre-calibrated and requires only one point validation.
Worldwide Approvals
The Universal IV CM Model has been approved for Class I, Div1, and Zone 0 hazardous locationss. FM, FMc, ATEX, as well as IECEx approvals are available.
Durability
Our Perm-A-Seal sensing element does not require epoxy coatings that wear out and require expensive servicing.
Eliminate Routine Maintenance
The Universal IV CM (Cut Monitor) is built upon the Drexelbrook expertise in RF Admittance that allows the electronics to ignore paraffin and other coatings that buildup on the probe.
0-50% in Light Oil & 0-80% in Heavy Oil
The Universal IV CM comes factory pre-calibrated to one of 11 pre-set ranges, for Light Oil (API Gravity > 25) and Heavy Oil (API Gravity < 25)
Cote Shield™ Universal IV ™ Cut Monitor Model
The proven Cote-Shield is designed into the Universal IV CM series and enables the instrument to ignore a pre-determined length of the sensing element.
Technology RF Admittance / Capacitance | |||
Supply Voltage 13-30VDC, 2-wire loop powered | |||
Ouput/Digital Protocol 4-20mA, HART Compatible with HART® | |||
Accuracy and Resolution | |||
Water Cut Range | Nominal Water CutVariance* | Water Cut Resolution** | |
0 to 1% | +/- 0.03 | 0.0002 | |
0 to 5% | +/- 0.04 | 0.0009 | |
0 to 10% | +/- 0.04 | 0.0009 | |
0 to 30% | +/- 0.12 | 0.0030 | |
0 to 50% | +/- 0.35 | 0.0080 | |
0 to 80% (Heavy Oil) | +/- 0.25 | 0.0035 | |
* The measurement accuracy of an inline, dynamic water cut measurement is dependent upon many process variables including: oil dielectric consistency, fluid velocity at the sample point, mounting geometry and homogeneity of the oil/water emulsion. The values above represent nominal water cut measurement variances for a properly installed sensor under consistent measurement point conditions. | |||
** The smallest water cut step that the instrument can resolve | |||
Load Resistance Maximum 550 ohms at 24 VDC Minimum 250 ohms for HART protocol | |||
Ambient Temperature -40°C to 85°C (-40°F to 167°F) | |||
Process Temperature | |||
Process Pressure | |||
Process Connection | |||
Integral or Remote Configuration 25 ft max cable length for remote configuration | |||
Response Time | |||
Supply Voltage Effect 0.2% of full scale max | |||
Process Temperature (Compensated) Up 232oC (450oF) - Transmitter will compensate for the effects of temperature when the water is in liquid state (Eg 0oC to 100oC at ambient pressure) | |||
Density Compensated Transmitter will compensate for the effects of changing density in the process flow | |||
Start-Up Time | |||
Configuration and Calibration | |||
Emission and Surge Protection | |||
Approvals
该产品由深圳市领导边摸边吃奶边做爽在线观看电子科技有限公司提供,销售商地址位于深圳市南山区前海路振业国际商务中心1206。请您仔细阅读产品使用说明书,正确使用。 如果想试用该产品,请以下单位:
领导边摸边吃奶边做爽在线观看电子主要销售通信设备、仪器仪表、电力设备、热工仪表、校准设备及工具配件。 |
欢迎关注领导边摸边吃奶边做爽在线观看网站平台
名称:极仪领导边摸边吃奶边做爽在线观看
客服电话:0755-23964199,86531914
E-mail:service@1001718.com
传真:0755-23964199
邮编:518052
|
||||