Warning: mkdir(): No space left on device in /www/wwwroot/Z4.com/func.php on line 127

Warning: file_put_contents(./cachefile_yuan/molaudo.com/cache/4e/a2d91/f95e1.html): failed to open stream: No such file or directory in /www/wwwroot/Z4.com/func.php on line 115
进口射频导纳物位开关Floating Roof Tanks_极仪领导边摸边吃奶边做爽在线观看


    1. 领导边摸边吃奶边做爽在线观看,国产精品伦一区二区三级视频,99无码熟妇丰满人妻啪啪,夜夜躁狠狠躁日日躁2022

      您当前的位置:>> 首页 > 产品中心 > 其它检测仪器 > 其它检测仪表 >> 进口射频导纳物位开关Floating Roof Tanks

      产品搜索:
      请在下列输入框内输入您要查找的产品名称。

      产品目录
      产品中心
      打印 字体缩放

      进口射频导纳物位开关Floating Roof Tanks的详细资料

      进口射频导纳物位开关Floating Roof Tanks 

      Floating Roof Tanks - Spill Prevention

      Overview

      Specifically designed for Floating Roof Tanks (Internal and External roofs) with Flexible Sensing Element 700-0005-594

      进口射频导纳物位开关Floating Roof Tanks 

      • Field Adjustable lengths from 1' to 18' (0.3 to 5.48 m) 12" to 216" (305mm to 5486mm)
      • Wetted Parts: 316SS 3/4" NPT Mounting, 3/16" FEP insulated flexible and adjustable cable, Non-Sparking Brass Sensor.

      Features:

      • Alarm trip points with any contact of internal or external roof.
      • Alarm trip points in "Sunken Roof" applications with less than 1" product.
      • One system will fit most floating roof tank application needs, reducing field spares.

      Inligent Electronics

      • Meets API 2350 regulations.
      • For use in safety related systems with requirements for functional safety for SIL2 (SIL 3 with Redundant Switch) In accordance to IEC61508-2, Sec. 7.4.3.1 1999 (Conforms to SIL, FMEDA Requirements - Exida)
      • No calibration or setpoint adjustments.
      • Automatically recognizes and ignores coatings to prevent false alarms.
      • Continuous Self-Test monitors circuits and sensing elements for faults
      • Remote or Integral Electronics

      ? 

      Dual Compartment Housing
      The dual compartment housing separates the customer wiring from the sensing element and operating circuits. The encapsulated power supply/terminal block design eliminates the� possibility of damage caused by moisture in the conduit.

      Self-Test Feature
      Automatic and Local or Remote Manual test functions ensure proper system operation.

      Auto Verification
      Each InliPoint is supplied with a continuous self-test feature that constantly monitors the integrity of not just the electronics, but the sensing element and interconnecting cable. If a fault is detected, the InliPoint Auto Verification feature alerts plant personnel.

       

      Manual Certification
      The InliPoint provides a method to manually test the entire system without removing the sensor from the tank. The Manual Certify Test checks that the Auto Verify circuits are operating and confirms the probe and cables are properly connected. The Manual Certify also allows the InliPoint electronics to sense changes in the probe that simulate contact with the media or a floating roof. This provides the user with a method to insure working performance without having to climb the tank. At the completion of the Certify test routine, the output is momentarily held in the alarm state so personnel can confirm that the control circuits connected to the Final Control Element are functioning properly.

      Technology:
      RF Admittance 

      Calibration: 
      None

      Modes Of Operation:
      High and Low Level 

      Repeatability: 
      2mm (0.08 inch) conductive liquids

      Response Time: 
      Less than one second

      Ambient Elctronic Temperature: 
      -40 to 70°C (-40 to 158°F) 

      Storage Temperature: 
      -40 to 85°C (-40 to 185°F) 

      Indicators: 
      LEDs: Green Power, Red Alarm 

      Self-Check: 
      AutoVerify automatically and continuously checks electronics and sensing element for faults. Manual Certify checks that the AutoVerify circuits are functioning. 

      Time Delay: 
      0-60 seconds, forward or reverse-acting

      Supply Voltage: 
      13-30 Vdc

      Power Consumption: 
      2 watts maximum

      Output: 
      8mA - Alarm 8mA - Normal 
      16mA - Normal 16mA - Alarm 
      22mA - Fault 5mA - Fault

      Housing: 
      Dual Compartment, Powder- Coated aluminum with two cable entries 

      Cable Entry: 
      M20x1.5 CENELEC
      3/4-inch NPT FM/CSA 

      Ingress Protection:
      IP66 NEMA 4X

      该产品由深圳市领导边摸边吃奶边做爽在线观看电子科技有限公司提供,销售商地址位于深圳市南山区前海路振业国际商务中心1206。请您仔细阅读产品使用说明书,正确使用。

      如果想试用该产品,请以下单位: 

       

      领导边摸边吃奶边做爽在线观看电子主要销售通信设备、仪器仪表、电力设备、热工仪表、校准设备及工具配件。

       

       

       

      扫一扫

      欢迎关注领导边摸边吃奶边做爽在线观看网站平台

      联系领导边摸边吃奶边做爽在线观看

      名称:极仪领导边摸边吃奶边做爽在线观看

      客服电话:0755-23964199,86564199

      E-mail:service@1001718.com

      传真:0755-23964199

      邮编:518052

      Copyright © 2024-2025 深圳市领导边摸边吃奶边做爽在线观看电子科技有限公司 版权所有网站地图 ICP备案号:粤ICP备15021421号
      极仪领导边摸边吃奶边做爽在线观看 制作维护

      0755-23964199
      0775-86564199

      微信扫一扫,给我发消息吧

       
      网站地图