      Fluke e-dwt-h电子自重测试仪的详细资料

      Fluke e-dwt-h电子自重测试仪
      The E-DWT-H has the operational versatility to calibrate and test a broad range of pressure measuring instruments including:

      • Analog gauges
      • Transducers
      • Calibrators
      • Sensors
      • Transmitters

       

      AutoTest™ lets E-DWT operators quickly define test points and adjust all of the range-dependent settings with a single function.
      The resolution and stability test used by the RPM4-E-DWT are set according to the range of the device under test. The upper limit setting is also set and provides range-based warnings and overpressure protection. While running AutoTests, the operator is prompted to set each sequential test point and test data is stored in the RPM4-E-DWT for recall or download. Typical test setup is quick and easy, but more complex tests can also be stored and reused.

      Deadweight tester performance with digital measurement convenience
      E-DWT-H offers precision, low measurement uncertainty and the stability over time of a conventional deadweight tester without the inconveniences associated with the piston-cylinders, weights, hand pumps, and interconnecting plumbing. Fluke e-dwt-h电子自重测试仪

      • No weights to load and unload or regularly send out for calibration
      • No need to know and correct for local gravity or ambient temperature
      • No piston-cylinder changes; switch Q-RPT ranges in seconds
      • Not sensitive to level or vibration
      • Able to set and read any pressure value exactly, no minimum increment limited by smallest available masses
      • Operates in any unit of measure while deadweight tester is typically limited to the pressure unit stamped on the mass
      • Perfect for applications that require setting a nominal pressure precisely on the device under test and measuring it, such as analog gauge calibration
      • On-board, AutoTest calibration routines and data acquisition
      • Interfaceable with a PC or laptop to allow for automated data acquisition
      • Two year calibration interval supported at measurement uncertainty of ± 0.025% of reading.
      • Easily recalibrated without crossfloating. Automated calibration of E-DWT-H is possible using COMPASS® for Pressure software.

      E-DWT-H breaks new ground, improving the hydraulic pressure calibration process. E-DWT-H is an electronic calibrator designed to replace mechanical, piston-cylinder and weight based deadweight testers. It’s a lighter, easier-to-use deadweight tester alternative that is at home in the lab or instrument shop, as well as in the field performing in-situ calibrations and tests. This complete hydraulic pressure calibration system combines the convenience and precision of continuous, realtime electronic pressure measurement with the simple and direct operation of high quality operator controlled pressure generation hardware. E-DWT-H one year measurement uncertainty is ± 0.02% of reading with ranges up to 30,000 psi. It can be configured to provide this uncertainty from its full scale down to 1% of its range. Built-in pressure generation and control hardware allow the operator to fill and prime the system under test and generate and precisely adjust pressure throughout the range with ease.


       

      • One-year measurement uncertainty is ± 0.02% of reading from 10% to 100% with one Q-RPT, and from 1% to 100% with two Q-RPTs
      • Low torque variable volume allows for pressure generation up to 200 MPa (30,000 psi) with minimal physical effort
      • Separate fine adjustment tool for maximum, superfine control resolution
      • User defined resolution and ready limits enable user to optimize performance based on DUT specifications
      • High pressure isolation valve and pressure relief valve protect the low pressure reference transducer from over pressure when high pressure reference transducer is active

      Ease of use

      • AutoRange feature optimizes measurement and safety features for the specific range of the instrument being calibrated
      • Simple rezeroing while vented at atmospheric pressure
      • Simple, objective pressure “ready/not ready indicator with user adjustable criteria to ensure repeatable results among operators
      • Not dependent on local gravity or ambient temperature
      • Sets and reads any pressure value directly in any unit of measure, without moving weights
      • Built-in priming system to fill system with test fluid and purge unwanted air to assure smooth operation
      • Optional foot switch accessory allows hands-free data collection when running AutoTests
      General
      Power requirements
        To RPM4-E-DWT: 12 V dc 1.2 A
        To AC to DC power supply: 100 V ac to 240 V ac, 50/60Hz
      Temperature range
        Storage: -20°C to 70 °C
        Operating: 10 °C to 40 °C
      Relative Humidity
        Storage: 0% to 100%
        Operating: 0% to 70%
      Weight
        1 Q-RPT: 12kg(26 lb) approximate
        2 Q-RPT: 14kg(30 lb) approximate
      Dimensions
        E-DWT footprint: 41.4 cm Wx37.1 cm D (16.3 inx14.6 in)
        E-DWT height: 26.9 cm (10.6 in), 33.6 cm (13.2 in) to max variable volume handle height
      Pressure ranges
      Dependent on Q-RPT(s) included in RPM4-E-DWT.
        200 MPa (30,000 psi) maximum with standard variable volume
        100 MPa (15,000 psi) maximum with high volume (-HV) variable volume
      Operating medium
        Delivered filled with oil (di-ethyl-hexyl sebacate) or dry
        Standard E-DWT-H compatible with Sebacate, silicon oils, propylene glycol, fully fluorinated liquids, partially fluorinated liquids, isopropyl alcohol , and distilled water. Option for Skydrol or mineral oil preparation.
      Reservoir capacity
        300 cc (18 in3)
      Variable volume displacement
        Standard: 3 cc (0.18 in3), 200 MPa (30,000 psi) maximum
        High: 7 cc (0.43 in3), 100 MPa (15,000 psi) maximum
      Filling and priming pump displacement
        3.7 cc (0.23 in3)
      TEST pressure connection
        DH500 female.
        Note: DH500 is a gland and collar type fitting for 6mm (1/4 in) coned and left hand threaded tubes equivalent to AE F250C, HIP HF4, 9/16-18 UNF, etc..
      Pressure Limits
        Maximum Working Pressure:
        Range of RPM4-E-DWT monitor’s Hi Q-RPT 200 MPa (30,000 psi) with standard variable volume
        100 MPa (15,000 psi) with high volume variable volume
        Maximum priming pump pressure: 700 kPa (100 psi)
        Maximum Working Pressure:
        with Lo Q-RPT selected: Range of RPM4-E-DWT monitor’s Lo Q-RPT
      communication ports:
        RS232 (COM1, COM2)

       

      Pressure measurement
      Warm up time
        15 minute temperature stabilization recommended from cold power up.
      Normal Operating Temperature Range
        10 °C to 40 °C
      Resolution
        Default: 0.01% of active range
        User adjustable to 1 ppm of Q-RPT maximum or 10 ppm of active AutoRange, whichever is larger
      Precision1
        ± 0.018% of reading or 0.0018% of Q-RPT span, whichever is greater
      Predicted Stability2
        One year: ± 0.0075% of reading
        Two year: ± 0.015% of reading
      Measurement Uncertainty3
        One year: ± 0.02% of reading or 0.002% of Q-RPT span, whichever is greater
        Two year: ± 0.025% of reading or 0.0025% of Q-RPT span, whichever is greater

       

       

      领导边摸边吃奶边做爽在线观看电子主要销售通信设备、仪器仪表、电力设备、热工仪表、校准设备及工具配件。有多功能多产品校准器、电能功率校准器、活塞式夜夜躁狠狠躁日日躁2022(气体、高压、液体、真空)、多功能电气安全校准器、示波器、频率计、万用表、阻抗国产精品伦一区二区三级视频、功率计、LCR数字电桥、音频国产精品伦一区二区三级视频、电容测试仪、电感测试仪、安规测试仪、直流电阻测试仪、网络国产精品伦一区二区三级视频、频谱仪、任意波形发生器、温度校准仪、数字测温仪、信号发生器、电源、电子负载、综合测试仪、信号源、滤波器测试仪、材料试验机、温度传感器、热像仪、变压器测试仪、噪声源、视频国产精品伦一区二区三级视频、过程校准仪、温度巡检仪、超级测温电桥、黑体炉、射频导纳物位开关、多点物位开关、音叉开关、射频导纳连续物位计、雷达液位计、超声波液位计、油中水含量国产精品伦一区二区三级视频、液位测量系统、磁致伸缩液位计、非接触固体雷达、压力传感器、过程表、压力变送器、气动控制器、高纯压力开关、隔膜片、冲液表、计量表膜片密封、材料实验机、食品质构仪、硬度实验机、数字测力计、PETPLUS特性粘度仪、布氏光学扫描系统、洛氏布硬度实验机、全自动显微硬度试验机、布氏硬度试验机、电动试验平台、单柱材料试验系统、双柱材料试验系统、浮球活塞夜夜躁狠狠躁日日躁2022、船用温度压力校验仪、点位测量系统、超声波开关、油/水界面开关、在线流体检测开关、多点开关、平板开关、浮顶罐溢出保护开关、静电放电干扰模拟器、雷击浪涌干扰模拟器、周波跌落模拟器、辐射抗扰度系统、脉冲群干扰模拟器、传导抗扰度测试系统、传导骚扰测试系统、辐射骚扰测试系统等仪器。 
      温馨小贴士:请您仔细阅读产品使用说明书,正确使用本产品。 

        

      公司:深圳市领导边摸边吃奶边做爽在线观看电子科技有限公司
      地址:深圳市南山区前海路振业国际商务中心1206

       

       

       

      扫一扫

      欢迎关注领导边摸边吃奶边做爽在线观看网站平台

      联系领导边摸边吃奶边做爽在线观看

      名称:极仪领导边摸边吃奶边做爽在线观看

      客服电话:0755-23964199,86531914

      E-mail:service@1001718.com

      传真:0755-23964199

      邮编:518052

      Copyright © 2024-2025 深圳市领导边摸边吃奶边做爽在线观看电子科技有限公司 版权所有网站地图 ICP备案号:粤ICP备15021421号
      极仪领导边摸边吃奶边做爽在线观看 制作维护

      0755-23964199
      0775-86531914

      微信扫一扫,给我发消息吧

       
      网站地图